The basic parameters that define a Pre-Engineered Steel Buildings are:




Building Width
No matter what primary framing system is used, the building width is defined as the distance from outside of eave strut of one sidewall to outside of eave strut of the opposite sidewall. Building width does not include the width of Lean-To buildings or roof extensions.

Building Length
The distance between the outside flanges of end-wall columns in opposite end-walls is the building length. It is a combination of several bay lengths.

Building Height
Building height is the eave height, which usually is the distance from the bottom of the main-frame column base plate to the top outer point of the eave strut. When columns are recessed or elevated from finished floor, eave height is the distance from finished floor level to top of eave strut.

Roof Slope (x/10)
This is the angle of the roof with respect to the horizontal. The most common roof slopes are 0.5/10 and 1/10. Any practical roof slope is possible.

End bay length
The distance from outside of the outer flange of end-wall columns to centerline of the first interior frame column.


Interior bay length
The distance between the centerlines of two adjacent interior mainframe columns. The most common bay lengths are 6 m, 7.5 m and 9 m.
 
Design Loads
Unless otherwise specified Zamil Steel Pre-Engineered Buildings are designed for the following minimum loads:
     - Roof Live Load: 0.57 kN/m2
     - Design Wind Speed: 110 km/h
 
Design for snow loads, earthquake loads, collateral loads, crane loads or any other loading condition, if required must be specified at the time of request for quotation.
Loads are applied in accordance with the latest American codes and standards applicable to Pre-engineered Buildings unless otherwise requested at the time of request for quotation.
Print page   Send to friend   Feedback
     Home  |  Terms of use  |  Privacy Policy  |  Contact Us  |  Site Map  |  Tiếng Việt                                                  Best view with screen resolution 1024 x 768
Copyright © 2008, Zamil Steel Viet Nam. All Rights Reserved
Address: Noi Bai Industrial Zone, Quang Tien Village, Soc Son District, Hanoi, Vietnam
Tel: (84.4) 3582 0800 - Fax : (84.4) 3582 0801 - Email:
marketing@zamilsteel.com.vn
History
Vision & Mission
Our Core Values
Our Logo
Key Personnel
Manufacturing Facilities
Engineering Capability
Awards & Accreditations
Zamil Group & its Affiliated Companies
Pre-Engineered Steel Buildings
Structural Steel
Open Web Steel Joist
MaxSEAM Roofing System
Building Components
Customer Testimonials
FAQs
Agriculture
Aviation
Commercial
Industrial
Institutional
Press Releases
Newsletters
Corporate Video
Product Literature
Recruitment
Pre-Employment
Work life
Career growth
Job performance
Area Offices
Certified Builders/Distributors
Application For a Certified Builder/Distributor
Request for Quotation
Subscribe